Boiler Losing Pressure
If your boiler pressure gauge reads below 1 bar, your boiler may lock out and stop working entirely. Pressure loss is one of the most common boiler problems — and while re-pressurising is a simple job you can do yourself, repeatedly losing pressure signals an underlying fault that a Gas Safe engineer needs to investigate.
Gas safety notice: Never attempt to work on gas pipes, open the boiler casing, or carry out any internal boiler repair yourself. All gas work must be carried out by a Gas Safe registered engineer. If you smell gas, leave the property immediately and call the National Gas Emergency line on 0800 111 999.
Common Causes
Leak in the heating system
The most common cause. Even a small weep on a radiator valve, pipe joint or boiler component will cause the pressure to fall gradually over days or weeks.
Faulty pressure relief valve (PRV)
The PRV is a safety device that opens when the pressure exceeds its limit. If it's worn or stuck open, it releases water even when the pressure is normal — causing repeated pressure loss.
Failing expansion vessel
The expansion vessel absorbs the pressure change as water heats up. If its internal membrane has failed, the PRV opens every time the boiler fires — draining pressure slowly.
Bleeding radiators
Releasing trapped air from radiators also releases a small amount of water. After bleeding, the system should always be re-pressurised using the filling loop.
Micro-leak in the heat exchanger
A hairline crack in the heat exchanger can cause pressure to drop. This is a serious fault and requires professional diagnosis.
What You Can Check Safely
These checks are safe for homeowners — no tools or technical knowledge needed
Check the pressure gauge
Locate the pressure gauge on the front of the boiler. Normal operating pressure is 1–1.5 bar when cold. If it reads below 1 bar, the system needs re-pressurising.
Re-pressurise via the filling loop
The filling loop is a braided silver hose beneath the boiler. Turn both valves slowly until the pressure gauge reads 1.5 bar, then close both valves fully. Never exceed 2 bar. If the pressure drops again within a day or two, call an engineer.
Check for visible leaks
Look around all radiator valves and pipe connections for damp patches, rust marks or dried white limescale deposits. Check under the boiler for any drips.
Check the overflow pipe outside
Find the plastic pipe that exits through an outside wall (usually under the boiler). If it is dripping constantly, this suggests a faulty pressure relief valve — call a Gas Safe engineer.
When to Call a Gas Safe Engineer
- The pressure drops more than once a fortnight
- You can see a drip or leak from any pipework, valve or the boiler itself
- The external overflow pipe is dripping continuously
- The boiler keeps locking out with a pressure-related fault code
- You cannot locate the filling loop or are unsure how to use it
Why Choose WarmaHome?
- Gas Safe registered engineers — legally qualified for all gas work
- Worcester Bosch Accredited Installers
- Family-run business covering Luton, Dunstable, Leighton Buzzard and Milton Keynes since 2008
- 4.9/5 from over 1,250 customer reviews
- Same-day and next-day appointments often available
- Transparent pricing — no hidden charges
Frequently Asked Questions
Need an engineer?
Same or next-day appointments across Luton, Dunstable, Leighton Buzzard and Milton Keynes.
Smell gas?
Leave the property immediately. Do not use any electrical switches. Call the National Gas Emergency line.
0800 111 999Why WarmaHome?
- Gas Safe registered
- Worcester Bosch Accredited
- 4.9/5 from 1,250+ reviews
- Luton & Bedfordshire based
- Since 2008