Worcester Bosch Boiler Error Codes: Full Guide

Modern Worcester Bosch boilers display fault codes when they detect a problem — making it much easier to diagnose what's gone wrong before calling an engineer. This guide explains the most common Worcester Bosch error codes and the likely action required.

If your boiler is displaying a code not listed here, refer to your boiler's manual or call a Gas Safe engineer.

EA229 — Condensate blockage or frozen condensate pipe

EA229 is one of the most common codes — and one of the few homeowners can resolve themselves. It indicates that the condensate pipe (which carries waste acidic water from the flue to a drain) has become blocked or frozen.

In cold weather, the most likely cause is a frozen section of the external condensate pipe. Thaw it by pouring warm water along the pipe from a jug. Once thawed, press the reset button to restart the boiler. If the code persists in warm weather, the condensate trap inside the boiler may be blocked and will need engineer attention.

EA229 in winter = frozen condensate pipe. Thaw with warm water, reset the boiler. If it recurs, insulate the external pipe section.

227 — Flame loss

Code 227 indicates that the boiler attempted to light but the flame was not reliably detected by the ionisation sensor, or that the flame went out unexpectedly during operation. Causes include a faulty gas valve, dirty or damaged ionisation probe, intermittent gas supply, or a combustion problem.

Try a single reset. If the code reappears, do not keep resetting — call a Gas Safe engineer to investigate the ignition and gas valve system.

D5 — Ignition failure

D5 indicates the boiler has failed to ignite after the maximum number of ignition attempts. Like code 227, this typically points to an ignition electrode fault, a gas supply issue, or a gas valve problem. A Gas Safe engineer will need to test the ignition system and gas valve.

C6 — Fan fault

The fan in a condensing boiler drives combustion gases safely out through the flue before and during firing. Code C6 indicates the fan is not reaching the required speed — which prevents the boiler from firing as a safety measure. The fan may be failing, the fan cable may be loose, or there may be a blockage in the flue. This requires engineer investigation.

E9 or EA — Overheat fault

E9 indicates the boiler has reached a dangerously high temperature and the overheat thermostat has cut it off. Causes include sludge on the heat exchanger (reducing heat transfer), a failing pump, or insufficient water flow through the system. A single reset can be tried, but if the code returns, the underlying cause must be investigated by a Gas Safe engineer — repeated overheating causes lasting damage to the heat exchanger.

What to do if your boiler shows a fault code

  • Note the exact code displayed — report it to the engineer when you call
  • Try one reset (hold the reset button for 3–5 seconds)
  • If the code returns quickly, do not keep resetting — call a Gas Safe engineer
  • If you smell gas, do not reset or operate any switches — leave the property and call 0800 111 999

Need expert advice from a local engineer?

WarmaHome are Gas Safe registered boiler engineers covering Luton, Dunstable, Leighton Buzzard and Milton Keynes. We'll give you a straight answer and a fair price.

Frequently Asked Questions

Get expert help today

Gas Safe engineers in Luton, Dunstable, Leighton Buzzard & Milton Keynes.

Worcester Bosch Boilers Guide

Guides, comparisons and error code references for Worcester Bosch boilers — the UK's best-selling boiler brand.

Worcester Bosch Boilers Hub

Why WarmaHome?

  • Gas Safe registered engineers
  • Worcester Bosch Accredited Installer
  • 4.9/5 from 1,250+ reviews
  • Family-run since 2008
  • Same or next-day available
Back to Advice Centre